Indoor Wall Sconces
Indoor wall sconces in this collection include linear up/down LED fixtures for architectural wall effects, compact directional models for focused bedside accents, and decorative shaded designs for living spaces. The main difference is how light spreads: along the wall, toward a nearby surface, or softly into the room. Compare light direction, fixture projection, and electrical compatibility before selecting a finish. For multi-room projects, organize mounting positions, preferred models, and quantities into a fixture schedule for a quote.
Showing 21–40 of 500 results

Westgate Architectural LED Wall Sconce CRE-01

Westgate Architectural LED Wall Sconce CRE-02

Westgate 15W/20W/25W 3000K/4000K/5000K LED Vanity Light Brushed Nickel LSC-18-MCTP-BN

Westgate 12W/18W/20W 3000K/4000K/5000K LED Vanity Light Brushed Nickel LSC-15-MCTP-BN

Westgate 25W 2,300LM 30K/35K/40K LED Wall Cylinder Light CMCW5

Westgate 30W 2,500LM 30K/35K/40K LED Wall Cylinder Light CMCW6

Westgate 30W 2,800LM 30K/35K/40K LED Wall Cylinder Light CMCW6

Westgate 40W 3,850LM 30K/35K/40K LED Wall Cylinder Light CMCW10

Westgate 40W 4,350LM 30K/35K/40K LED Wall Cylinder Light CMCW10

Utopia Lighting Rondo 2-Direct/Indirect Wall Rondo 2-Direct/Indirect Round Wall Mount Light

Utopia Lighting Rondo2-RGBW Wall Rondo 2-RGBW Round Wall Mount Fixture

Utopia Lighting Rondo2-TW Wall Rondo2-TW Tunable White Round Wall Mount Fixture

Utopia Lighting Wiol LED Diffused Wall Mount Light

Utopia Lighting Rondo 2 Wall Rondo 2 Round Wall Mount Fixture

Utopia Lighting ULW4-2G-BED Overbed Bi-Directional Light

Westgate 50W 5,500LM 3500K/4000K/5000K Perforated Up/Down LED Wall Light Powder Coated White WCPL-UD-4FT-50W-MCT-D

Westgate 25W 2,750LM 3000K/ 4000K/ 5000K Louver Up/Down LED Wall Light Powder Coated White WCLP-UD-2FT-25W-MCT-D

Lighting Spot 26 3W 395lm 5000K Gray Aluminum, Dark Gray Aluminum LED Wall Light LS2-1880-DG

Lighting Spot 26 30W 1950lm 3CCT selectable Black LED Wall Light LSH-UD30W-3CCT

Lighting Spot 26 16 in. 15W 5CCT selectable LED Wall Light LS-WL16-BM15W-5CCT
About Indoor Wall Sconces
How to Choose Indoor Wall Sconces: Light Direction, Clearance, and Controls
Indoor wall sconces should be chosen for the light they put into a room, not just how the fixture looks on a product page. A narrow corridor, bedside wall, and bathroom mirror present different problems: glare at eye level, shadows on a task, or a fixture exposed to moisture. This guide explains the decisions that aren't obvious from finish filters: beam direction, wall projection, electrical compatibility, and maintenance. Check those details before settling on a model or repeating it throughout a project.
Quick Picker: Match the Fixture to the Installation
- 4-foot hallway: Prioritize shallow projection and a shielded light source at eye level.
- 24-inch bedside table: Check switch reach and where light falls on a book.
- 48-inch bathroom mirror: Confirm the location rating before finalizing side-light positions.
- 8-foot living room ceiling: Pair wall accents with ceiling lights for general illumination.
- Dining table beneath a feature fixture: Rely on pendant lights for tabletop coverage.
Hallway and Bedside Light Direction: Control Glare Before Style
In a 14-foot hallway, two wall-mounted fixtures can produce an uncomfortable view of bright LEDs even when the floor looks adequately lit. Start by considering the approach direction and whether the source is visible at standing eye level. Diffusers and shielding can soften the view, while tight directional beams may highlight texture but leave nearby surfaces in shadow. A reading position beside a bed adds another consideration: the light should reach the page without shining toward the sleeper.
If the source sits directly in the usual sightline, shortlist a shielded or diffused optic rather than simply reducing wattage. Review the fixture's distribution drawing or installed-light photos before choosing the pair.
Wall Sconce Height and Projection: Check Corridor Clearance
A 4-foot-wide corridor may have enough wall space for a tall fixture yet not enough clearance for a deep one. Mounting centers around 60 to 66 inches above the floor are often used as a design starting point, but furniture, users, and beam direction can change the appropriate height. Projection is a separate safety check.
Under applicable ADA protruding-object rules, wall-mounted objects with leading edges above 27 inches and no higher than 80 inches cannot extend more than 4 inches into a circulation path. If your planned sconce exceeds that limit in a covered path, select a shallower fixture or revise its location with the designer. Measure the furthest projection from the finished wall before rough-in.
Bathroom Wall Sconces: Choose the Required Moisture Rating
Two fixtures beside a 48-inch bathroom mirror may look right on the elevation, but their location rating still has to suit the site. A dry-location listing does not establish suitability near a shower or where moisture exposure requires a damp- or wet-location luminaire. The bathroom itself is not automatically one single rating zone; the actual exposure and applicable installation rules matter.
If spray or persistent moisture can reach the proposed mounting position, select a model specifically listed for those conditions rather than using a dry-only interior fixture. Check the exact SKU's location rating, mounting orientation, and mirror clearance before placing the electrical boxes.
LED Wall Sconce Specs: Lumens, Color Quality, and Dimming
For 12 matching guest-room sconces, consistent color and control behavior matter more than selecting the highest wattage. Some products have fixed 3000K output, while other verified listings include selectable color temperature; neither feature proves that the model is dimmable. Compare the individual specification sheets:
- Delivered lumens: Usable light output, not electrical draw.
- CCT: Warm or cool appearance in Kelvin.
- CRI: Color rendering, relevant near finishes and artwork.
- Dimming protocol: Phase-cut, ELV, or another stated method.
- Input voltage: The permitted supply range for that exact SKU.
If the twelve fixtures share a dimming zone, confirm each driver and its compatible control before standardizing the order. Test one complete fixture-and-control combination first.
Integrated LED vs. Replaceable-Bulb Sconces: Plan for Maintenance
In ten guest rooms, replacing an ordinary lamp is a different maintenance task from servicing an integrated LED assembly. This collection includes fixtures with built-in LED sources and examples with E26 sockets for separate bulbs. An integrated design may require a manufacturer-approved module, driver, or fixture replacement when components fail; a socketed design allows a compatible lamp to be changed. Neither approach is automatically better for every project.
If straightforward relamping is a priority, favor a socketed model with a clearly specified base and lamp limit. Confirm whether the bulb is included and whether an enclosed shade affects lamp suitability. Record the light-source type for each selected SKU.
Hardwired Wall Sconce Replacement: Backplate, Box, and Voltage
Replacing a fixture over a 4-inch round wall box can reveal a smaller backplate, mismatched mounting holes, or unfinished wall behind the old light. Measure the existing box, backplate footprint, and projection before ordering. Also record the supply voltage, ground connection, switching arrangement, and mounting orientation. Some Lumera sconce variants are listed for 120V while others have a wider input range; the finish alone won't tell you which driver is inside.
If the new fixture cannot be mounted safely to the existing installation, plan the correct electrical device box or approved repair instead of improvising an adapter. Have a qualified electrician verify the wiring and support, then compare the dimensional drawing before purchase.
Ordering Indoor Sconces for a Multi-Room Project
For a 24-sconce apartment renovation, group fixtures by model, finish, voltage, source type, dimming circuit, and location rating. Lumera offers trade accounts for eligible businesses with volume and project quotes; approved account holders can separately apply for Net-30 credit terms. Keep similar-looking driver and finish variants on separate schedule lines.
Request an Indoor Wall Sconce Project Quote
For repeated corridors, bedrooms, or residential units, request a wall sconce project quote with a coordinated schedule. Include:
- Preferred models, finishes, and quantities by room
- Mounting height, projection limits, and existing wall boxes
- Input voltage, dimmer type, and switching locations
- Dry, damp, or wet rating where the location requires it
This helps distinguish lookalike fixtures with different electrical requirements.
Indoor Wall Sconce FAQs
What is the difference between a wall sconce and a bathroom vanity light?
A wall sconce provides localized accent or task light, while a bathroom vanity light is generally selected to illuminate a mirror and grooming area. A pair of suitable sconces can work beside a mirror, but the beam direction and moisture rating still matter. If broad mirror coverage is the main goal, compare bathroom vanity lights before choosing the final arrangement.
How high should hallway sconces be installed?
There is no universal mounting height. A centerline around 60 to 66 inches above the finished floor is a common starting point, but the fixture's height, glare, nearby doors, and walking clearance can change the placement. In accessible circulation paths, check the applicable four-inch protrusion limit for objects at specified heights. Confirm the finished position before rough-in.
Can interior wall lights be installed on a covered porch?
Only when the exact fixture is listed for the conditions at that porch. An indoor-looking design is not evidence of a damp- or wet-location rating, and a roof does not prevent every form of wind-driven rain. For an exposed or potentially wet entrance, compare appropriately rated outdoor wall lights rather than installing a dry-only sconce.
Are all LED wall sconces dimmable with a standard wall switch?
No. Dimming depends on the specific LED driver or replaceable lamp and its compatible control method. A fixture requiring ELV dimming may not work correctly on an ordinary forward-phase control; mismatches can cause flicker or limited range. Check the model's driver specifications and compatible LED dimmer switches before buying multiple fixtures for one circuit.
Do wall sconces use replaceable bulbs or integrated LEDs?
Both configurations exist. Integrated LED sconces contain a built-in light source, while socketed models accept a specified replaceable lamp, such as an E26-base bulb. For the latter, check the base, maximum wattage, and enclosure restrictions before selecting A19 LED bulbs. Don't assume the lamp comes with the fixture or that an integrated unit has a standard replaceable bulb.