Bathroom / Exhaust Fans
Bathroom exhaust fans remove excess moisture and odors while helping keep bathrooms properly ventilated. Choose between fan-only and fan-with-light configurations, including models with selectable airflow or built-in sensing where available. Start with the CFM needed for the room, then compare sone rating for noise and confirm housing dimensions, duct connection, and mounting requirements. For shower or tub locations, verify that the exact fan is approved for the intended wet-area installation before ordering.
Showing 1–20 of 122 results

Panasonic FV-01VCN1 WhisperAir Repair Ceiling Mounted 9 CFM Quiet Spot Air Purifier

Orbit Ventilation Fan Deluxe Grille ODG

Orbit 80140 Cfm Deluxe Fan Light, Dc Motor, Humidity Sensor ODU814LH

Orbit Osp 70 L Motor with Fan Light Grille OSP70LF

Orbit 80 Cfm Deluxe Fan, 0.7 Sone, Humidity Sensor OD80H

Orbit Ventilation Fan Deluxe Housing ODH

AirZone Fans SE90MH Ventilation Fan Light Kit 90 CFM 0.7 Sones

AirZone Fans SES80HLED Ventilation Fan Light Kit 80 CFM 1.1 Sones

AirZone Fans SES80LED Ventilation Fan Light Kit 80 CFM 1.1 Sones

AirZone Fans SQ-LED-LK Ventilation Fan Light Kit

AirZone Fans SES-LED-LK Ventilation Fan Light Kit

AirZone Fans SNPLEDLK Ventilation Fan Light Kit

Orbit 110 Cfm Deluxe Fan Light, 0.6 Sone, Humidity Sensor OD110LH

Orbit 120 Cfm Deluxe Ventilation Fan with Flour. Light, 1.5 Sone OD120L

Orbit 90 Cfm Deluxe Ventilation Fan with Flour. Light, 0.7 Sone OD90L

Orbit 90 Cfm Economy Plus Ventilation Fan, 1.5 Sone OEP90

Orbit 70 Cfm Standard Plus Fan Light, 3.5 Sones OSP70L

Orbit Ventilation Fan Economy Plus Housing OEPH

Orbit 70 Cfm Standard Ventilation Fan, 4 Sones OS70

Orbit Fan Light Grille Module (LED) OFLGML
About Bathroom / Exhaust Fans
How to Choose Bathroom Exhaust Fans: CFM, Noise and Installation Fit
Choosing a bathroom exhaust fan starts with the airflow your room needs, but the CFM rating is only part of the decision. Sound level, duct resistance, ceiling space, mounting orientation, and the way the fan is controlled all affect the finished installation. For replacements, measure the existing housing opening and duct connection before choosing a model. For new construction, establish the ventilation requirement and duct route before the ceiling is closed.
Fan-Only vs. Fan-and-Light Bathroom Exhaust Fans
If the bathroom already has adequate overhead or vanity lighting, a fan-only bathroom exhaust fan keeps ventilation and lighting independent. This makes sense in a 5-by-8-foot bathroom where a separate fixture already lights the room. You can select the exhaust fan for its airflow, sound rating, and installation fit without also evaluating an integrated light.
If the only practical ceiling location must handle both functions, compare bathroom exhaust fans with lights. Check the light output and switching requirements separately from the fan's CFM. A combination unit can reduce the number of ceiling fixtures, but it does not reduce the room's ventilation requirement.
Size Bathroom Ventilation by CFM and Room Layout
CFM means cubic feet per minute. For intermittent bathroom ventilation, the Home Ventilating Institute recommends approximately 1 CFM per square foot for bathrooms up to 100 square feet, with a minimum recommendation of 50 CFM for smaller rooms. An 8-by-10-foot bathroom therefore starts at roughly 80 CFM. Check applicable local requirements and the fan's performance at the resistance of the planned duct system before settling on a model.
Bathrooms larger than 100 square feet generally require a fixture-based calculation. Common HVI guidance assigns 50 CFM each to a toilet, shower, or standard bathtub and 100 CFM to a jetted tub. A divided bathroom may also require more than one pickup point or a separate exhaust fan for an enclosed toilet compartment. Choose a layout that removes air from the areas generating moisture instead of relying on one grille far from the shower.
Compare Sone Ratings After Meeting the Airflow Requirement
A sone rating describes perceived fan sound; a lower rating means quieter operation under comparable test conditions. Noise matters in a bathroom next to a bedroom, but selecting the quietest model is not helpful if it cannot deliver the needed airflow through the installed duct. Compare fans within a suitable CFM range first, then review sound ratings and housing dimensions. A shallow ceiling cavity can rule out an otherwise attractive quiet model.
Duct Length and Static Pressure Affect Delivered Airflow
The duct is part of the ventilation system. Long runs, several elbows, undersized connections, compressed flexible duct, and restrictive exterior caps all add resistance. As static pressure rises, a fan may deliver less air than its headline CFM rating suggests. For a replacement, don't automatically reduce a new fan's outlet to fit an older, smaller duct. Check the manufacturer's duct requirements and performance information instead.
If the blower needs to be located away from the bathroom or the planned duct arrangement calls for a remote unit, review inline duct fans as a different system design. An inline fan is not a universal fix for an excessively restrictive duct; airflow, pickup location, duct sizing, and sound still need to be evaluated together. Bathroom exhaust must terminate outdoors, not inside an attic or crawl space.
Humidity Sensors, Motion Sensors and Fan Timers
Automatic ventilation controls serve different purposes. A humidity-sensing fan responds to moisture conditions, a motion sensor responds to occupancy, and a countdown timer runs the fan for a selected period. For a bathroom used primarily for showers, humidity response can be useful; for a separate toilet room, occupancy-based operation may be more appropriate. Confirm whether sensing is integrated into the fan or requires an external device.
When planning separate occupancy-based switching, review occupancy and motion sensors only after checking the selected sensor's load rating and approval for controlling that specific fan. Many occupancy devices are intended for lighting circuits and should not automatically be treated as compatible motor controls.
Match Fan Controls to the Motor and Wiring
A timer and a fan-speed control are not the same product. A timer manages run time; a speed controller changes the operating speed of a compatible motor. Some exhaust fans have built-in speed settings or proprietary controls, and standard wall fan-speed devices may be intended for AC ceiling fans rather than bathroom ventilation motors.
If adjustable speed is part of the design, compare fan speed controls only after confirming the fan manufacturer's supported control method, motor type, electrical rating, and wiring requirements. For automatic shutoff after a shower, use a separately verified compatible timer instead of assuming that a speed controller also provides countdown operation.
Check Wet-Area Approval, Mounting and Replacement Air
A ceiling exhaust fan is not automatically approved for installation directly over a shower or tub. Check the exact product's permitted location, mounting orientation, and any required electrical protection before placing it in a wet area. The manufacturer's instructions and applicable local code govern the installation.
The fan also needs a path for replacement air to enter the room. A tightly sealed bathroom door can restrict airflow even when the fan is correctly sized. Check the door undercut or other approved transfer-air path, the available ceiling depth, and the location of framing and duct connections. Hardwired electrical work and required mechanical connections should be completed by qualified installers.
Bathroom Exhaust Fan Specifications to Confirm Before Ordering
- Airflow: Required CFM for the bathroom size, fixtures, and ventilation strategy.
- Sound: Sone rating at the relevant operating point.
- Ducting: Outlet diameter, route, expected resistance, and outdoor termination.
- Housing: Opening dimensions, ceiling depth, and supported mounting orientation.
- Lighting: Integrated light output and separate switching requirements, where applicable.
- Controls: Built-in sensors, external timers, and motor-control compatibility.
- Location: Approval for the intended bathroom or shower-area installation.
For multiple bathrooms, prepare a schedule showing the quantity, required CFM, fan-only or fan-and-light configuration, duct size, housing restrictions, and control method for each room. Keeping these details together helps avoid ordering similar-looking fans with different mechanical or electrical requirements.
Bathroom Exhaust Fan FAQs
How many CFM do I need for a bathroom exhaust fan?
For intermittent ventilation in bathrooms up to 100 square feet, a common HVI guideline is about 1 CFM per square foot, with at least 50 CFM for smaller rooms. A 75-square-foot bathroom therefore starts around 75 CFM. Larger bathrooms are commonly sized by adding the recommended airflow for each plumbing fixture. Confirm local requirements and duct-system performance.
What does the sone rating mean on a bathroom fan?
Sones describe perceived sound level. Lower values indicate quieter operation under comparable rating conditions. Evaluate noise after determining the fan's required airflow, since a quiet unit that cannot provide enough ventilation is not a good replacement. Check the published rating for the specific model and operating setting.
Should I buy a fan-only model or a bathroom fan with a light?
Choose a fan-only unit when the room already has adequate lighting or when the lighting and ventilation should operate independently. Choose a fan-and-light combination when one ceiling location needs to serve both functions. In either case, size the exhaust airflow for the bathroom rather than choosing the fan by its lighting feature.
Is a humidity-sensing fan better than a timer?
A humidity sensor responds to moisture conditions, while a timer runs for a preset interval. Humidity sensing can help when users forget to leave the fan running after a shower. A compatible timer gives predictable run-on time. Choose the control behavior based on the room's use and confirm its compatibility with the selected fan.
Can bathroom exhaust fans vent into an attic?
No. Bathroom exhaust should terminate outdoors rather than discharge humid air into an attic, crawl space, or ceiling cavity. The duct, backdraft provisions, and exterior termination affect the installation as much as the fan itself. Check the entire exhaust route when replacing an existing unit.
Can a bathroom exhaust fan be installed over a shower?
Only if the exact model is approved for that location and the installation meets its stated electrical and mounting conditions. A fan being marketed for bathrooms does not automatically make it suitable for the area directly over a shower or tub. Verify the product documentation and applicable local requirements before installation.