Tape Light
LED tape light creates concealed linear illumination for coves, cabinets, shelves, displays, toe kicks, and architectural details. Choose the tape by operating voltage, output per foot, color temperature, and installation environment, then plan the complete run around its cut interval and maximum run length. Low-voltage systems also require a compatible driver sized to the connected wattage, while channels, diffusers, connectors, and feed locations affect the finished installation. Confirm all system components before ordering total footage.
Showing 21–40 of 1402 results

Diode LED Channel Bundle, FLEXIBLE MUD-IN, 96 in, Aluminum, Frosted Silicone Cover, 2 open end caps, 2 closed end caps (DI-CPCHB-MUDFLX-96AL)

Diode LED SQUARE & 45º Vertical Channel Stopper Pair (DI-1912)

Diode LED Wet Location Strip Light End Caps for DAZZLE, 25 Pack (DI-0842-25)

Diode LED Channel Bundle SLIM 48 in Frosted Lens 1 open end cap 1 closed end cap 2 mounting clips

Diode LED Channel Bundle A1 Channel 48 in Fully Diffused Cover 1 open end cap 1 slotted end cap 1 closed end cap 2 standard mounting clips

Diode LED Channel Bundle SQUARE 48 in Architectural Frosted Lens 1 open end cap 1 closed end cap 4 mounting clips

Diode LED Channel Component Profile SLIM 96 in 10 Pack

Diode LED Channel Component Profile SQUARE 48 in 10 Pack

Diode LED Channel Bundle A2 Channel 96 in Architectural Frosted Satin Lens 2 open end cap 2 closed end cap 4 mounting clips

Diode LED Channel Bundle A3 Channel 96 in Architectural Clear Lens 2 open end cap 2 closed end cap 4 mounting clips

Diode LED Channel Bundle 45 48 in Premium Diffusion Lens 1 open end cap 1 closed end cap 4 mounting clips

TL-2JUMP65-2 Tape Light Accessory 24in IP65 Jumper Single Color

TL-5JUMP24-HD Tape Light Accessory 24in HD Jumper RGBW

STLWD-3018-16 Standard Tape Light IP54 Dim to Warm 16.4Ft

TL-6JUMP6-HD Tape Light Accessory 6in HD Jumper RGBTW

TL-4JUMP24-HD Tape Light Accessory 24in HD Jumper RGB
6in Linking Cable for 2PIN 4MM-5MM COB Tape Light

Lighting Spot 26 16.4ft. 24V LED Tape Light LS-TPC-7.8W-24V-5M

Lighting Spot 26 16.4ft. 24V LED Tape Light LS-TPC-12.5W-24V-5M

ELCO Lighting E15-24-16 LED Tape Light 1.5W/ft 16 ft
About Tape Light
How to Choose LED Tape Light
LED tape light should be planned as a system, not as a roll of LEDs. Start with the finished run length and the lighting effect you need, then confirm operating voltage, watts and lumens per foot, color temperature, CRI, cut interval, maximum run length, and location rating. For low-voltage systems, the driver, connectors, wire, channels, and controls all have to match the tape before installation begins.
- A concealed cabinet or shelf run: start with tape that fits the available width and required cut interval.
- A longer cove or millwork detail: establish maximum run length and feed points before choosing spool length.
- A low-voltage system: match the tape to compatible LED drivers and power supplies.
- A rigid finished linear fixture instead of field-assembled flexible lighting: compare LED linear lighting.
12V vs. 24V Tape Light: Match the Whole System
Most flexible tape systems operate from a constant-voltage power supply, and the tape voltage must match the driver output exactly. Lumera's current assortment includes both 12V and 24V products, with 24V widely represented across longer and higher-output runs. Some product families also use other supply arrangements, including 120V, so voltage should always be checked at SKU level.
A 24V system is generally more tolerant of longer low-voltage runs than an equivalent 12V system because voltage drop represents a smaller percentage of the supply. That doesn't remove the product's published maximum-run limit.
For a 6-foot cabinet with the driver nearby, either voltage may work when the product supports the application. A 30-foot architectural run makes voltage drop and feed placement much more important.
Decision rule: choose one operating voltage for the run, then keep the tape, driver, connectors, and other voltage-specific components compatible with that system.
Size the Driver From Watts per Foot and Finished Length
For low-voltage tape, total connected wattage determines driver capacity. Multiply the tape's rated watts per foot by the actual powered footage, then select a compatible constant-voltage driver according to the driver's required sizing margin.
For example, a 16-foot run using tape rated at 5 watts per foot creates an 80-watt connected load before applying the manufacturer's driver-sizing requirements. Spool length doesn't matter if only part of the spool is connected.
The driver also determines much of the control behavior. Phase-cut, ELV, 0-10V, and other dimming arrangements require compatible drivers and controls.
Decision rule: calculate the completed run first, then select the driver. If dimming is required, establish the control method before ordering the power supply and coordinate it with Lumera's LED dimmers and controls.
Maximum Run Length and Cut Interval Are Different Specifications
Spool length tells you how much tape is supplied; maximum run length tells you how far the exact tape can be powered as one run under its specified conditions. Cut interval tells you where the tape may actually be shortened. All three numbers can be different.
Current Lumera products illustrate the variation. One Diode LED tape lists a 2.5-inch cut interval and 16.4-foot maximum run, while another lists 4-inch cut points and a substantially longer permitted run. These values are product-specific, so they should never be generalized across the category.
A 101-inch shelf also won't necessarily accept exactly 101 inches of tape if the product can only be cut every four inches.
Decision rule: map every finished length against both the cut interval and maximum run before ordering footage or installing channels.
Choose Output, CCT and CRI for the Surface Being Lit
Tape light ranges from subtle accent illumination to higher-output task and architectural lighting. Lumens per foot describe light output, while watts per foot determine electrical load. More output isn't automatically better because it also increases driver capacity and thermal requirements.
Color temperature changes the visual character of the installation. CRI becomes especially important when tape illuminates wood, stone, merchandise, food, artwork, or other finishes at close range. Current Lumera products include both 90+ and 95+ CRI options, but those ratings belong to specific products rather than the entire category.
A display shelf and a concealed ceiling cove can therefore use very different tape even when both runs are 10 feet long.
Decision rule: choose output for the task first, then coordinate CCT and CRI with the materials and adjacent lighting.
Channels, Diffusers and Connectors Affect the Finished Result
Flexible tape can disappear visually only when the mounting detail is planned well. Aluminum channels provide a straight mounting surface and can help manage heat, while lenses or diffusers soften the appearance of individual LED points. This is particularly useful above glossy counters, inside visible shelving, or wherever the tape itself can be seen.
Connectors are equally specific. Tape width, conductor count, contact layout, and product family can determine which tape-to-wire or tape-to-tape connector fits. Lumera's current Diode LED range, for example, uses connector widths such as 8 mm, 10 mm, and 12 mm on different systems.
Decision rule: select the channel, diffuser, and connector after the exact tape SKU is known. Don't order accessories from nominal voltage alone.
Dry, Damp and Wet-Location Tape Need Different System Components
Environmental rating applies to the complete installation, not simply the LED strip. Lumera currently carries tape products with different dry, damp, and wet-location specifications, including sealed IP-rated products on particular models. Protective construction can also change tape dimensions and connector compatibility.
A wet-location strip connected with indoor-only connectors or powered by a dry-location driver in an exposed location does not create a complete wet-location system.
For a shower niche, covered exterior detail, or other moisture-prone installation, check the tape, termination method, wiring, channel, and driver individually. Hardwired line-voltage connections and driver enclosures also need to remain appropriate and accessible; Lumera's junction boxes and driver enclosures include options for housing compatible power equipment.
Decision rule: use the exposure at the most vulnerable component to set the environmental requirements for the whole run.
What to Confirm Before Ordering Tape Light
- Finished run length: measure each run separately rather than using total project footage alone.
- Operating voltage: match tape, driver, and voltage-specific accessories.
- Watts per foot: calculate the connected load before sizing the driver.
- Lumens per foot: match output to task, accent, or architectural lighting needs.
- CCT and CRI: coordinate appearance with adjacent lighting and illuminated finishes.
- Cut interval: confirm the tape can finish cleanly at the required dimension.
- Maximum run: plan feed points before walls, cabinets, or channels are closed.
- Tape width: match channels and connectors to the actual product.
- Dimming: choose the driver and control method as one compatible system.
- Environment: verify every component for dry, damp, or wet-location use as required.
Ordering Tape Light for a Project
For repeated millwork, retail, hospitality, cove, or display runs, create a schedule for each section showing length, voltage, watts per foot, CCT, location rating, feed point, driver, channel, connector, and control method. This prevents the most common ordering problem: having the tape on site without the compatible parts needed to power and finish it.
Once the runs are defined, larger material schedules can be submitted through Lumera's project quote request.
LED Tape Light FAQs
What is the difference between 12V and 24V LED tape?
Both are low-voltage tape systems, but the driver output must exactly match the tape. A 24V system is generally better suited to longer low-voltage runs because it is less sensitive to voltage drop than an equivalent 12V system. Always stay within the maximum run published for the exact tape.
How do I choose an LED driver for tape light?
Multiply the tape's watts per foot by the actual connected footage, then select a constant-voltage LED driver with the matching 12V or 24V output and the capacity required by its sizing instructions. If the tape must dim, the driver's dimming method also has to match the control.
Can LED tape light be cut anywhere?
No. Cuttable tape can only be shortened at the manufacturer's marked cut points. The spacing between those points varies by product, so measure the finished detail against the published cut interval before finalizing cabinet, channel, or cove lengths.
Do I need an aluminum channel for LED tape?
Not every product requires the same mounting method, but channels are useful when the installation needs a straight finished line, physical protection, heat management, or a diffuser to reduce visible LED dots. Confirm the tape width and channel compatibility before ordering the extrusion.
Can tape light be dimmed?
Yes, when the tape system uses compatible dimming equipment. In most low-voltage systems, the driver determines the wall-control method. Choose the driver and compatible dimmer together rather than assuming every dimmable LED tape works with the same control.
Can LED tape light be used outdoors?
Yes, when the exact tape and every exposed system component are rated for the environment. Wet-location tape alone isn't enough; connectors, terminations, wiring, channel components, and the driver also need appropriate ratings. Check the complete system before using flexible lighting outdoors or in moisture-prone locations.