LED Tube Lights
LED tube lights retrofit compatible fluorescent fixtures in offices, garages, shops, utility areas, and other linear-lighting applications. Choose between T8 and T5 formats by the existing lamp and socket, then match tube length, base, and operating method—ballast-compatible, ballast-bypass, or hybrid. After compatibility is established, compare lumen output, CCT, wattage, and dimming requirements. For retrofit work, record the existing lamp, ballast, sockets, and fixture wiring before ordering replacement tubes.
Showing 21–40 of 145 results
Damar 39242A LED12T8 / 5CCT / 3FT / HYBRID / SS
Damar 39241A LED8T8 / 5CCT / 2FT / HYBRID / SS
Damar 38682A LED19T8 / BLUE / 4FT / DR
Damar 38645C LED17T8 / 850 / U1 / DR / SS 17W (D)
Damar LED33T8/8FT/DR/SS

Damar 38677A LED33T8 / 835 / 8FT / DR / SS FA8

Damar 38804B LED22T5 / 841 / 4FT / DR / SS 22W
Damar 38645B LED17T8 / 841 / U1 / DR / SS 17W
Damar 38645A LED17T8 / 830 / U1 / DR / SS 17W (D)
Damar 38689A LED18T8 / GREEN / 4FT / DR
Damar LED12T8/U1/DR/SS 12W
Damar 38645D LED17T8 / 865 / U1 / DR / SS 17W
Damar 38637C LED9T8 / 841 / 2FT / DM / SS (D)

Damar 38691A LED19T8 / BLP / 4FT / DR (D)
Damar 38639E LED18T8 / 865 / 4FT / DM / SS (D)
Damar 38638A LED12T8 / 830 / 3FT / DM / SS (D)
Damar 38638C LED12T8 / 841 / 3FT / DM / SS (D)
Damar 38639D LED18T8 / 850 / 4FT / DM / SS (D)
Damar 38639A LED18T8 / 830 / 4FT / DM / SS (D)
Damar 38639B LED18T8 / 835 / 4FT / DM / SS (D)
About LED Tube Lights
Type A, Type B, or Type C: Start With the Electrical Setup
Before choosing LED tube lights by length or wattage, determine how the replacement will receive power. Some LED tubes work with a compatible fluorescent ballast, others require the fixture to be rewired for direct input, and some use a dedicated LED driver. These approaches involve different parts, labor, and maintenance requirements. If the existing lamps sit in a suspended-grid ceiling, it is also worth comparing the tube conversion with complete LED troffer fixtures before committing to a building-wide relamp.
How Type A, Type B, and Type C LED Tubes Differ
Type A (ballast-compatible) lamps operate through a supported fluorescent ballast. They can allow a straightforward lamp replacement when the ballast and lamp have been confirmed compatible. The ballast remains part of the system, however, and may still need replacement later. Check the lamp manufacturer's ballast compatibility list, including the ballast model and operating conditions, before ordering.
Type B (ballast-bypass) lamps receive their specified electrical supply without the fluorescent ballast. Converting the fixture requires wiring changes, and the correct arrangement depends on the individual lamp. This option can remove an aging ballast from the maintenance plan, but it is not a simple plug-and-play replacement.
Type C (external-driver) systems replace the fluorescent ballast with a compatible LED driver. Their performance and control capabilities depend on the paired lamp and driver, so a Type C designation alone does not guarantee a particular dimming range. Some hybrid Type A/B lamps permit either compatible-ballast operation or a later direct-wire conversion; follow the exact product instructions for each mode.
Ballast Bypass: Wiring, Lamp Holders, and Safety
Type B installation deserves a separate compatibility check because rewiring changes how the lamp holders receive power. In common single-ended configurations, the specified supply connections are at one end of the tube. Double-ended designs use connections at opposite ends. The two arrangements must not be substituted for each other unless the lamp manufacturer explicitly permits the installation.
Lamp holders, sometimes called tombstones, may be shunted or non-shunted. Single-ended line-and-neutral designs commonly require non-shunted holders, while requirements for double-ended designs vary. Check the instructions for the actual lamp rather than making a decision from the fixture's appearance. A qualified electrician should perform the conversion, use the required parts and labels, and verify the modified fixture before it is returned to service.
T8, T5, and T12: Match the Tube and Base
The T number describes nominal tube diameter in eighths of an inch. A T8 is approximately 1 inch in diameter, a T5 is approximately 5/8 inch, and a T12 is approximately 1-1/2 inches. Common T8 lamps use a G13 medium bi-pin base, while many T5 lamps use the smaller G5 base. Other lengths and lamp designs can have different ends, so the code and base on the existing product should be checked rather than inferred from diameter alone.
For a T12 retrofit, identify the original ballast, lamp holders, and fixture condition before ordering. An older fluorescent ballast may not support a ballast-compatible LED tube. A properly specified direct-wire conversion or complete fixture replacement may be more appropriate, but the decision should be based on the particular equipment and labor involved. Nominal tube length is not an exact physical measurement; confirm the manufacturer's length and fit information for unusual or older installations.
Color Temperature, Lumens, and Matching Existing Rooms
Once electrical compatibility and physical fit are established, compare the output of the replacement. Lumens describe light output, while correlated color temperature (CCT) affects whether the illumination appears warmer or cooler. A replacement with the same wattage as the old fluorescent tube will not necessarily deliver the same light level or distribution through the existing fixture lens.
For a corridor or office with multiple fixtures, keep lamp type, lumen output, and CCT consistent across the area where possible. If a particular product offers selectable color temperature, record the installed setting so future maintenance replacements match. For a mixed relamping project that also includes general screw-base and reflector bulbs, the broader LED bulbs and lamps collection covers other lamp formats; those products are not substitutes for a tube simply because their lumen ratings are similar.
Dimming Depends on the Lamp, Ballast, and Driver
Do not assume that all Type A tubes are non-dimmable or that every Type C system supports the same controls. Whether an LED tube can dim depends on its approved ballast or driver, control method, and manufacturer compatibility information. Some direct-wire lamps are non-dimmable, while certain dedicated-driver systems support 0-10V or other control methods.
If the room requires dimming, occupancy-based operation, or another lighting-control feature, establish that requirement before choosing the retrofit type. A lamp that fits the sockets but cannot operate with the specified controls is not a suitable replacement. Confirm any required control wiring and electrical work before finalizing the order.
When a Complete Fixture or LED Retrofit Kit Makes More Sense
Replacing just the tubes can be useful when the existing fixture, lens, reflector, and sockets remain in good condition. If those parts are damaged, discolored, or repeatedly failing, changing the lamps alone may not correct poor light distribution or recurring service calls. A compatible LED retrofit kit is another possible approach when it is designed for the existing luminaire and preserves the parts approved to remain in service.
For a utility room, garage, or open service corridor where the existing fluorescent strip housing is due for replacement, compare complete LED strip light fixtures. For grid-ceiling offices, complete troffers may fit the project more naturally. The key question is which components are actually being retained: lamps only, an approved fixture housing, or none of the old assembly.
Checklist Before Ordering LED Tube Lights
- Existing lamp: T5, T8, or T12 designation; nominal and actual length; base and pin configuration.
- Electrical method: Type A, Type B, Type C, or an explicitly supported hybrid configuration.
- Ballast or driver: Exact model and documented compatibility, or the required replacement components.
- Fixture condition: Lamp holders, reflector, lens, housing, and access for a safe retrofit.
- Light quality: Lumen output, color temperature, and consistency with adjacent fixtures.
- Controls: Dimming requirements and compatibility with the intended control system.
- Installation: Approved wiring method, conversion labeling, and qualified electrical work where required.
LED Tube Lamp FAQs
What is the difference between Type A, Type B, and Type C LED tubes?
Type A operates through a compatible fluorescent ballast. Type B requires the ballast to be bypassed or removed and receives power through the lamp holders in its specified arrangement. Type C uses a dedicated external LED driver. The correct choice depends on the fixture, its condition, installation labor, and required controls.
Is a ballast-bypass LED tube safe?
It can be when the lamp and conversion method are approved for the fixture and a qualified electrician follows the required wiring, lamp-holder, protection, and labeling instructions. Single-ended and double-ended arrangements are not automatically interchangeable. Never install a direct-wire lamp in an unmodified fluorescent fixture unless the lamp is explicitly approved for that operating mode.
Can I replace a T12 fluorescent tube with an LED tube?
Possibly, but do not assume a simple lamp swap will work. Many older T12 installations have ballasts that are incompatible with ballast-compatible LED lamps. Identify the ballast, socket arrangement, and fixture condition first, then choose an approved conversion method or a complete fixture replacement.
How can I tell whether a tube is T5 or T8?
Check the code printed on the lamp and its dimensions. T5 describes a tube approximately 5/8 inch in diameter; T8 is approximately 1 inch. Many T5 lamps use a G5 base and common T8 lamps use G13, but also confirm the exact length and end configuration before ordering.
Are LED tube lamps dimmable?
Only when the specific lamp and its ballast or driver support the intended dimming method. Type classification alone is not enough. Review the compatibility documentation and match the control and electrical configuration before buying multiple replacement lamps.
Should I retrofit the existing fixture or replace it?
Retrofitting often makes sense when the housing and optical components are sound and an approved conversion method is available. Replace the entire fixture when its sockets, lens, reflector, or housing are failing, or when the new lighting and control requirements cannot be met with a suitable conversion.