Alteck

Lumera Electric carries 186 Alteck fixtures, and the whole range is exterior: 131 outdoor wall sconces, 38 outdoor flush mounts and 17 outdoor pendants. Every one is an integrated LED fixture, wet-location rated, ETL listed and TRIAC dimmable, and 183 of the 186 offer a color temperature you select at the fixture. Output runs from 150 to 2,407 lumens on 5 to 44 watts, with 119 parts at 120V and 67 rated 120V to 277V. Finishes are led by black at 134 products, then brass at 18, bronze at 17, stainless steel at 10 and brushed at six. Trade pricing and bulk quotes are available on volume orders.

When Every Fixture Is Wet Rated, the Decision Moves to IP Rating and Color Range

Most exterior brands make you check the location rating on every part. Alteck does not, because all 186 fixtures here are wet-location rated, all are ETL listed, all use an integrated LED, and all dim on TRIAC control. That uniformity is useful, but it also removes the filters buyers normally lean on. What actually separates one Alteck part from another is the ingress rating, the color temperature range, and whether the fixture is built to throw light down instead of sideways.

Three fixture types, three different mounting jobs

The catalog is narrow on purpose. There are no landscape fixtures, no bollards and no floods, so if the job needs those, they come from another brand inside outdoor lighting rather than from this page.

Outdoor wall sconces are the bulk of it at 131 products, going on entries, facades, garage walls and address positions, with IP44 on 88 of them and IP65 on 43. Outdoor flush mounts at 38 products belong on porch and soffit ceilings and covered walkways, with IP44 on 32 and IP65 on six. Outdoor pendants at 17 products suit covered entries and porches with ceiling height, and every one of them is IP44 only.

Wet rated and IP rated are two different questions

Wet location is the NEC-facing rating that says the fixture may be installed where water can hit it. IP, short for ingress protection, is the numeric rating for how much water and dust the housing actually keeps out. Every Alteck part clears the first test. Only 49 of the 186 clear the higher version of the second.

IP44 covers splashing water from any direction. IP65 adds dust-tight construction and resistance to low-pressure water jets. On a sheltered entry wall the difference rarely shows. On an unprotected coastal elevation, a soffit that gets pressure washed, or a wall under a roofline that dumps runoff, IP65 is the specification to hold out for. Note that none of the 17 pendants offer it, so a fully exposed hanging position is outside what this range is built for.

3CCT and 5CCT are not the same range

Selectable CCT means the fixture has a switch that changes its color temperature during install, so one part number covers several looks and a distributor holds fewer SKUs. Alteck uses two versions and they are not interchangeable, which matters when you are matching new fixtures to an existing elevation.

  • 3CCT, on 132 products. Selects 3000K, 4000K or 5000K. The bottom of this range is 3000K, so it cannot go warm.
  • 5CCT, on 51 products. Spans 2700K through 5000K, which adds the warmer settings residential clients usually ask for.
  • Three products carry no selectable option and ship at a fixed color temperature.

The practical consequence is that if a project standardizes on 2700K, roughly three quarters of this range cannot deliver it and the 3CCT parts will read cooler than the rest of the building. Confirm the range before you mix the two on one elevation. The setting is made at the fixture during install, not from a control system, so it is worth agreeing before the crew is on a ladder.

Dark Sky and ADA on exterior walls

The Dark Sky friendly flag appears on 31 products, meaning the optics direct light downward to limit uplight and glare, and every one of them is a wall sconce. If the jurisdiction has an outdoor lighting ordinance, or the project sits near an observatory or a protected area, that group of 31 is the whole eligible pool in this brand. Shielding, mounting height and beam control are covered in the lighting guides.

ADA projection is flagged on 136 products, 100 wall sconces and 36 flush mounts. Since ADA limits how far a fixture can protrude into a circulation path, that flag is what matters on a commercial entry, a corridor or a covered walkway rather than on an open facade. Timers and dusk-to-dawn scheduling for exterior circuits sit in timers and time switches.

Reading an Alteck part number

Alteck uses the cleanest numbering of any brand in this catalog. Five segments, each carrying real information, and they hold across all 183 parts that follow the standard format. AW0174-5CCT-W-BK reads as a wall sconce, model 0174, with the 2700K to 5000K selectable range, wet rated, in black.

The leading letters are the fixture type, with AW for a wall sconce, AP for a pendant and AFM for a flush mount. Four digits follow as a sequential model number. The CCT segment states the selectable range, where 3CCT means 3000K to 5000K and 5CCT means 2700K to 5000K.

A single W then marks wet location, and it is on every part in the range. The last segment is the finish code.

The finish codes are worth learning because black dominates so heavily that everything else is a special order in practice. Bronze and brass each use several codes rather than one, so filter on the finish family rather than a single suffix. The twelve codes cover 183 of the 186 parts, the same three exceptions that fall outside the standard number format.

BK is black and it dominates with 131 products, so anything else narrows the design choice sharply. BSS is stainless steel on ten. Bronze comes under three codes, DB on eight, DBO on seven and PBZ on two.

Brass is spread even wider, appearing as PAB on seven products, PB on five, then PWB, BB and PPB on two, two and one. BA is a brushed finish on six and WH is white on two. Where a finish family uses several codes, filter on the family rather than one suffix.

Dimming and voltage before you order

Every listing in this range states TRIAC dimming, which is forward-phase control and the same technology a conventional wall dimmer uses. That points you at standard dimmers rather than anything exotic, and it means the low-end performance depends on how well the dimmer handles a small LED load.

One caution. A reverse-phase or ELV control is a different technology, and pairing it with a fixture built for forward-phase is a common source of flicker and buzz. Nothing in this range is listed for the products in ELV and 0-10V dimmers, so treat that collection as the wrong shelf for Alteck unless a specific listing says otherwise.

On voltage, 119 parts are 120V and 67 are rated 120V to 277V. On a commercial exterior circuit running at 277V that second group is the only one that works, and it is a little over a third of the range, so check early rather than after the schedule is set. Dusk-to-dawn switching, if the fixture does not include it, comes from a separate device in photocells.

Numbers that change from part to part

The brand-level facts are uniform, so these are the fields that actually decide the part. Read them on the listing, and remember that exterior work is inspected against the local ordinance as well as the code, which the installation and code disclaimer covers.

  • Ingress rating. IP44 on 137 parts, IP65 on 49. This is the single most useful filter in the range.
  • Color temperature range. 3CCT reaches 3000K at its warmest, 5CCT reaches 2700K. Three parts are fixed.
  • Supply voltage. 120V on 119 parts, 120V to 277V on 67.
  • Delivered lumens. The range spans 150 to 2,407 lumens, so a small sconce and a large one are not remotely comparable.
  • Wattage. From 5W to 44W, which matters when you are totaling a circuit of exterior fixtures.
  • Rated life. Listings show 54,000 hours on 158 parts and 50,000 hours on 28.
  • Dark Sky. Flagged on 31 wall sconces only, and on no flush mount or pendant.
  • ADA projection. Flagged on 136 parts across sconces and flush mounts.
  • Finish availability. Black covers 131 parts. Any other finish narrows your design choices sharply.

Exterior rating and control questions on Alteck

Do I need IP65 or is IP44 enough?

IP44 handles splashing water and suits a sheltered wall, a recessed entry or a soffit under a generous overhang. IP65 adds dust-tight construction and resistance to water jets, which is what you want on a fully exposed elevation, near sprinklers, on a coastal site, or anywhere the fixture will be pressure washed. Only 49 of the 186 parts here are IP65, so if the job demands it, filter for it before you shortlist designs.

What is the difference between a 3CCT and a 5CCT Alteck fixture?

The selectable range. A 3CCT part switches between 3000K, 4000K and 5000K. A 5CCT part covers 2700K through 5000K, so it reaches warmer. If your project standard is 2700K, only the 51 parts marked 5CCT can hit it, and putting a 3CCT fixture beside one set to 2700K will show a visible difference at night.

Which dimmer should I pair with these fixtures?

The listings across this range state TRIAC dimming, which is forward-phase control, so a conventional LED-rated wall dimmer is the right family. Confirm the dimmer is rated down to the fixture's wattage, since a 5W sconce on a dimmer with a high minimum load will flicker or refuse to strike. Vendor documentation elsewhere has described ELV control on some Alteck parts, so if the control package is already purchased, verify the individual listing before you commit.

Can I use these fixtures indoors?

Yes. A wet-location rating is the highest of the three location classifications, so it covers dry and damp interiors as well. The practical questions become whether the color temperature range suits the room and whether an exterior-grade housing reads correctly inside, not whether the fixture is permitted.

How do I tell whether a fixture is Dark Sky friendly?

It is a per-product flag rather than a brand-wide property, and only 31 products carry it, all of them wall sconces. Dark Sky friendly means the optics push light downward and limit what escapes upward as glare and skyglow. If a local outdoor lighting ordinance applies, treat those 31 as the eligible list and confirm the specific fixture against the ordinance wording.

Are there Alteck landscape or flood fixtures?

No. This range covers wall sconces, flush mounts and pendants only, all of them building-mounted. For in-ground uplighting, path lighting, bollards or wall washing, the fixtures come from other brands in the catalog, and the low-voltage landscape lines are a separate system with their own transformers.