LED Area & Parking Lot Lights
LED area lights in this collection include Type III distributions for perimeter parking rows, Type IV forward-throw options near property lines, and Type V optics for central lot areas. These pole-mounted fixtures direct light differently across drive aisles and parking spaces, so one beam pattern won't suit every position. Choose by pole location, coverage pattern, and mounting compatibility before comparing detailed specifications. For multi-pole projects, prepare a fixture schedule with locations and quantities for a quote.
Showing 481–483 of 483 results

Lighting Spot 26 150W 18800-21000lm 5000K Brown LED Area Light LS2-S-G07-150W-5K

Lighting Spot 26 100W 12500-14000lm 5000K Brown LED Area Light LS2-S-G07-100W-5K

Westgate 50W 6,900LM 4000K LED Flood Area Light Dark Bronze LFCO-50W-40K
About LED Area & Parking Lot Lights
How to Choose LED Area Lights for Parking Lots: Optics, Poles, and Controls
LED area lights for parking lots should be specified around the ground to be illuminated, the existing pole layout, and neighboring properties, not a headline wattage. The same shoebox-style fixture can produce very different coverage when its optical distribution or mounting height changes. This guide helps project buyers compare beam patterns, pole and bracket compatibility, electrical ratings, controls, and installation constraints before choosing a SKU. It also identifies when a different exterior fixture will better serve the job, so the lighting schedule reflects the actual site.
Quick Picker: Match the Fixture to the Outdoor Job
- 20-foot perimeter pole: Start with an inward-facing Type III or IV distribution.
- 24-foot center-lot island: Evaluate Type V coverage around the pole.
- Building wall above an 8-foot walkway: Choose LED wall pack lights.
- 10-foot covered parking entrance: Review LED canopy lights.
- Freestanding sign 30 feet away: Consider aimable LED flood lights.
Type III, IV, and V Distribution: Choose by Pole Position
On a 110-by-160-foot parking lot, a perimeter pole faces different constraints from a central island pole. Type III creates an asymmetrical field with lateral reach; Type IV pushes the strongest part of the beam farther forward; Type V forms a more symmetrical footprint. These are optical patterns, not levels of brightness. Actual light footprints still change with mounting height and the individual luminaire.
Decision rule: If the pole stands close to a property line, shortlist an appropriate asymmetric optic and examine backlight rather than choosing Type V by habit. A center-lot pole may benefit from a symmetric pattern. Compare the IES files against the stall and drive-aisle layout before choosing a distribution.
Pole Height and Spacing: Check the Pavement, Not Just the Wattage
At a 24-foot mounting height, moving two poles another 15 feet apart can leave a dark midpoint even with powerful luminaires. Pole height, spacing, output, and beam shape must be evaluated together; a fixed feet-between-poles formula cannot establish uniform lighting for every lot. A photometric layout using the selected fixture's IES file estimates maintained foot-candles across parking stalls, travel aisles, crossings, and the corners.
If the predicted minimum light level or uniformity falls short of the project's criteria, adjust the layout or optical distribution before simply increasing watts. Request a layout that uses the actual pole coordinates and approved lighting targets, then select fixture count and output from that result.
Slip-Fitter vs. Direct-Arm Mounting: Check the Pole and Wind Load
A 22-foot square pole with a flat bolt pattern may need a direct arm, while a fixture equipped with a 2-3/8-inch slip fitter requires a compatible round tenon. Those mounting methods are not interchangeable, and an older pole may have hardware that differs from its original drawings. Record the pole shape, tenon diameter or bolt spacing, bracket arrangement, and fixture weight before ordering a replacement.
If you are adding a second head, have the pole's allowable effective projected area (EPA), wind load, foundation, and total attached equipment checked by a qualified professional. Structural capacity cannot be inferred from the lamp wattage. Confirm the selected model's approved mounting kit and installation drawing before placing the order.
LED Area Light Specs: Lumens, Voltage, CCT, and Surge Protection
A site with both 120-277V and 277-480V circuits cannot use a single driver specification merely because the housings look alike. These voltage ranges can identify different product variants, not an installer-selectable setting. For a 16-head retrofit, check each location's supply and compare the following before locking the schedule:
- Lumens and efficacy: Delivered output and electrical input at the stated configuration.
- CCT: Consistent light appearance across the property.
- Input voltage: The exact driver's permitted range.
- Dimming: Supported protocol, such as 0-10V where specified.
- DLC status: Exact-model qualification if a utility rebate requires it.
- Surge protection: Documented protective rating, when provided.
If the supply is 480V, choose a specifically compatible SKU; don't assume every fixture has universal input. Check the individual specification sheet.
Photocell Receptacles and Dimming: Plan the Site's Control Strategy
Across 16 parking-lot poles, dusk-to-dawn switching and after-hours dimming are separate tasks. A three-contact twist-lock receptacle generally supports basic photocontrol; five- or seven-contact configurations can accommodate additional control conductors for compatible dimming or networked equipment. Extra contacts do not, by themselves, mean the driver supports the desired features.
If the site needs scheduled output reduction, confirm the receptacle, driver, and control-node compatibility before committing to a simple on/off configuration. Use commercial lighting controls for coordinated circuits or lighting timers when clock-based operation is appropriate. Record the switching scheme, 0-10V needs, and any future expansion in the electrical schedule.
Property-Line Glare and Outdoor Ratings: Verify the Installed Conditions
For a drive aisle only 15 feet from neighboring homes, unwanted backlight can be more important than the fixture's total lumen output. BUG ratings separate backlight, uplight, and glare; compare those values against the local lighting ordinance and the actual photometric layout. A house-side shield may help on a compatible fixture, but its availability must be confirmed for the selected model.
If rain can strike the luminaire, specify a suitable wet-location listing and approved orientation. For a metal-halide retrofit, check existing voltage, mounting brackets, conductor entries, and grounding before removing equipment. A qualified electrician should handle the line-voltage installation and verify the completed outdoor connections. Finish by comparing the chosen fixture with the site's documented conditions.
Ordering LED Parking Lot Fixtures for a Commercial Project
For a 36-head retrofit, group quantities by optic, mounting height, attachment, voltage, control arrangement, and location. Lumera offers trade accounts for eligible businesses and volume or project quotes. Approved businesses can separately apply for Net payment terms. When the plan is coordinated, submit your site-lighting fixture schedule so differing optical and electrical variants are identified.
Request an LED Area Lighting Quote
For a new parking lot or multi-pole retrofit, request an LED area lighting quote with the actual site requirements. Have these ready:
- Pole count, heights, locations, and a site plan
- Required distribution types or photometric targets
- Tenon or arm details and circuit voltage
- Dusk-to-dawn, dimming, and exposure requirements
- Fixture quantities or preferred model numbers
This gives the project team a workable basis for comparing suitable configurations.
LED Area and Parking Lot Lighting FAQs
What is the difference between an LED area light and an LED wall pack?
An LED area light typically distributes light across open ground from a pole or arm, while a wall pack lights the building perimeter from a wall-mounted position. A parking lot with central poles needs different optics and mounting from a service entrance on the building. Select the fixture family according to the mounting surface and the actual ground coverage required.
Should I choose Type III or Type V parking lot light distribution?
Type III is asymmetric, making it a useful starting point for rows along the edge of a lot; Type V distributes more evenly around a central pole. Type IV may suit some property-line locations requiring greater forward throw. The final choice must be tested against pole positions and the actual IES distribution, not decided from the optical label alone.
How far apart should LED parking lot light poles be?
There is no universally correct spacing distance. A 20-foot pole and a 30-foot pole can require different spacing and outputs to meet the same ground-level lighting criteria. The usable distance depends on optics, maintained lumens, pole layout, and site geometry. Review calculated foot-candles and uniformity from a photometric plan before selecting the number of poles or luminaires.
Do LED area lights come with a dusk-to-dawn photocell?
Some fixtures include a photocontrol, some accept an optional twist-lock unit, and others require external switching. A receptacle alone does not mean the sensor is included. If automatic dusk-to-dawn operation is required, compare compatible photocells and photocontrols against the fixture's receptacle, load, and voltage. Confirm the exact model configuration before ordering an entire site.
How can I reduce glare and light spill from parking lot lights?
Start with the optic and pole location, then evaluate backlight, uplight, and glare data against the site's boundaries. Shielding can help when the fixture supports it, but dimming alone may not correct poor aiming. Lumera's glare-reduction guide explains the importance of shielding and positioning. Verify compliance using the actual outdoor photometric layout.
Can I reuse existing poles when replacing metal-halide area lights?
Often, but only after checking pole capacity, fixture EPA, bracket compatibility, supply voltage, and the condition of existing wiring. A new LED head may require a different tenon adapter or attachment pattern. Review suitable conduit fittings and connectors if the electrical entry must change. Have a qualified electrician and, where necessary, a structural professional verify the installation before ordering.