Exit Signs & Emergency Lighting

An egress package has two halves, the signs that mark the way out and the lights that keep the path visible when power fails, and this collection carries 524 products across both. Utopia supplies dedicated units, remote heads, and New York and Chicago approved models, while Nora fills the page with strip lights, wraparounds, and panels ordered in integral-emergency versions. Exit signs get their own subcollection below.

Buying Emergency Lighting as a Package, Not a Pile

Egress work goes smoother when the order mirrors the code logic: signs mark the route, illumination keeps it walkable through an outage, and every device involved has to prove itself with a listing and a test schedule. Battery units are commonly expected to carry their load for a minimum of 90 minutes, which is the number inspectors ask about first.

The sign half of the package lives in its own exit signs subcollection, where face count, color, and mounting get decided. The rest of this page covers the illumination half.

Dedicated Units, Remote Heads, and City Approvals

Utopia carries the classic hardware on the current page: self-contained emergency lights, remote heads that run off a host unit's battery to stretch coverage into stairs and corners, and jurisdiction-specific models, including New York approved and Chicago approved versions for the two cities that keep their own rules.

That last detail saves failed inspections. Where a city enforces its own approval list, the product listing has to say so explicitly, because a generic unit with the right national listing still gets rejected at the local level.

Emergency Capability Inside Ordinary Fixtures

The other half of the page is Nora general lighting ordered with the backup already inside: strip lights, wraparounds, and backlit panels in EM versions, some adding a built-in motion sensor and the panels carrying a remote test switch. Buying the everyday fixture and its emergency function as one SKU keeps a ceiling cleaner than bolting a battery unit beside every third fixture.

The same pattern runs through the wider catalog, and the LED panels collection shows it on the general ceiling side with battery-backed options of its own.

Utility ceilings follow the same thinking through the strip lights range; match any fixture chosen there against the EM versions on this page before ordering the two halves separately.

Even the humble screw-in socket joins in, since battery-backup bulbs sit in the A19 lamps range for the closets and small rooms nobody wants to rewire.

Testing, Placement, and the Wiring Line

A compliant system is bought once and tested forever. The routine most jurisdictions follow pairs a brief monthly function check with a full annual discharge run, so accessible test switches, like the remote test switches on the Nora panels here, pay for themselves in ladder time.

Placement answers to the path, not the floor plan. Corners, stair landings, direction changes, and door hardware all want light on them when the building goes dark, which is exactly where remote heads earn their keep.

For retrofit cases, battery-backed LED drivers and conversion hardware are worth a check, and since every one of these devices ties into building wiring, installation and the inspections that follow belong with a licensed electrician.

Exit Sign and Emergency Lighting Questions

How long does emergency lighting have to run in an outage?

The figure inspectors look for is a minimum of 90 minutes of battery operation, and the rating on each product listing is what proves it. Local rules govern the details, so the authority having jurisdiction always gets the final word on a permit job.

What is a remote head?

A lamp head with no battery of its own, wired back to a host unit that powers it during an outage. Remote heads stretch one battery across stairwells and corners, and the host's capacity has to cover every head connected to it, a match the listings spell out.

Do New York or Chicago require special emergency lights?

Yes. Both cities maintain their own approval requirements on top of national listings, and this collection carries models marked New York approved and Chicago approved for exactly that reason. For work in either city, buy only units whose listing states the local approval.

Is an integral emergency fixture better than a separate unit?

They solve different problems. An integral version keeps the ceiling clean and cuts the device count, which suits new work and finished spaces. A separate unit installs independently of the fixture choice, which suits retrofits, and most buildings end up with a sensible mix of both.